HVM40B


Notes

  • Available with multiple power cord options for most mains configurations.
  • Available with handle and rack mount options.

Specification

DESCRIPTION specification conditions VALUE
Operational Temperature RangeOP TEMP0 to 50 °C
Operational HumidityHumidityNon Condensing0 to 80 %
Storage Temperature RangeSTORAGE TEMP °C
Case DimensionsCase DimensionsMetric9.0 W x 3.5 H x 7.25 D cm
WeightWeightImperial4 lbs
Electrical InputInput50 - 60 Hz, 0.5 Amps Maximum100 - 250 VAC
Measured VoltageMeasured VoltageDC Only500 to 40,000 VDC
Input ImpedanceInput Impedance10 GΩ
Input HV ConnectorHV-Insulated 40 kVAlden F310RX
Input Return ConnectorBinding Post
Accuracy (High)Accuracy (High)2,000 – 40,000 Volts+/- 0.4 %
Accuracty (Low)Accuracty (Low)500 – 2,000 Volts+/- 1.0 %
Resolution4.5
Sampling Rate2
DisplayLED
Case DimensionCase DimensionsImperial22.86 W x 8.89 H x 18.415 D in
Weight1.8
fuseFuseSlow Blow0.5 A / 250 VAC