2098 Series
10 to 14 kV, 35 mA, 420 W, Regulated, Programmable


Features
Features
- ARC/Short Protected
- Current Monitor
- Fixed output
- Front Panel Meter
- Metal Case
- Regulated
- Voltage Monitor
Applications
Products
Part # | VI | Input Type | PI | VO | PO | IOP | IOS | Volt Reg. | Ripple | Line Reg. | Stability | Control Type | Control Range | Op. Temp. | TCOEFF | Store Temp. | Humidity | Altitude |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
V | W | V | W | mA | mA | % VDC | % VPP | % VDC | % VDC | % VO | °C | % / °C | °C | % | Ft. | |||
CS2098L120+14 | 120 | AC | 500 | 10000 - 14000 | 420 | 35 | 20 | < 1 | < 5 | < 1.0 | < 0.5 | Potentiometer | 70 - 100 | 0 to 50 | 0.02 | -40 to 85 | 0 to 95 | 0 to 10000 |
Notes
- This power supply requires adequate ground connection for operation, failure to provide ground may result in failure of the power supply.