52014


Notes

  • The voltage and current rating for the 52000 series parts can be achieved only by complete emersion in dielectric oil such as Shell Diala or equivalent. Contact factory when other dielectric use is intended.

Specification

DESCRIPTION specification conditions VALUE
Peak Inverse VoltageVRRM48000 V
Maximum Average Output CurrentIFAVMAt 25 °C Ambient4 A
Maximum Leakage CurrentIRAt VRRM, 25 °C Ambient100 μA
Maximum Bridge Output VoltageVBO24000 V
Maximum Forward Voltage DropVFAt 55 °C, Per Leg9 V
Maximum Surge CurrentIFSMAt 8.3 mS, Per Leg400 A
DimensionA7.900 in
DimensionB9.000 in
Number of BoardsBoards4