DESCRIPTION | specification | conditions | VALUE |
---|---|---|---|
Peak Inverse Voltage | VRRM | 48000 V | |
Maximum Average Output Current | IFAVM | At 25 °C Ambient | 6 A |
Maximum Leakage Current | IR | At VRRM, 25 °C Ambient | 100 μA |
Maximum Bridge Output Voltage | VBO | 24000 V | |
Maximum Forward Voltage Drop | VF | At 55 °C, Per Leg | 9 V |
Maximum Surge Current | IFSM | At 8.3 mS, Per Leg | 400 A |
Dimension | A | 11.000 in | |
Dimension | B | 12.000 in | |
Number of Boards | Boards | 6 |