Specification
DESCRIPTION | specification | conditions | VALUE |
---|---|---|---|
Maximum Continuous Operating Voltage DC | MCOV (VDC) | 275 V | |
Maximum Continuous Operating Voltage AC | MCOV (VAC) | 250 V | |
Maximum Continuous Power Rating | PMAX | 10 W | |
Maximum Discharge Capacity | WMAX | 22,500 J | |
Maximum Clamping Voltage | VC | Vc @ Ip | 1200 V |
Maximum Clamping Voltage Condition | IP | 10 A | |
Varistor Voltage DC Test Condition Minimum | VNMIN | VMIN ≤ V ≤ VMAX at Ip | 440 V |
Varistor Voltage DC Test Condition Maximum | VNMAX | VMIN ≤ V ≤ VMAX at Ip | 660 V |
Varistor Voltage DC Test Condition at Current | Ip | 0.5 A |