CT1000V6AA40


Notes

  • High Current Assembly

Specification

DESCRIPTION specification conditions VALUE
Peak Inverse Voltage VRRMPer Leg 400 V
Maximum Applied Input VoltageVRMS140 V
Maximum Leakage Current IRAt VRMS 100 μA
Maximum Leakage Current IRAt VRRM, 25 °C Ambient 1000 μA
Maximum Forward Voltage Drop VFAt 40 °C Ambient, At Rated Output Current1.5 V
Maximum Average Output Current IFAVMAt 40 °C Ambient, Forced Air Cooling at 800 LFM 1000 A
Maximum Surge Current IFSMAt 8.3 mS, TJ = 150°C 10960 A