DCH3034P1



Specification

DESCRIPTION specification conditions VALUE
Operational Temperature Range OP TEMP0 to 60 °C
Operational Humidity HumidityNon Condensing 0 to 95 %
Operating Altitude Altitude0 to 10000 Ft
Storage Temperature Range STORAGE TEMP °C
Input Voltage VI12 V
Maximum Output Voltage VO30000 V
Maximum Output Power PO1.2 W
Temperature Coefficient TCOEFF0.3 % / °C
Input TypeDC
Maximum Input Power PI2 W
Maximum Output Current - Primary IOP40 µA
Voltage Regulation Volt RegAt Dynamic Load 18 % VDC
Ripple (Volts Peak to Peak) RippleAt Full Load, Nominal Input < 1 % VPP
Stability StabilityOver 8 hours, after 30 minute warm-up. At 25 °C ambient, fixed load, and fixed input.< 0.2 % VDC
Control TypeProportional
Voltage Range ControlledControl Range0 - 100 % VO