HRS10-15
Notes
- No data indicates the component is a standard recovery device and no TRR data is taken.
- Add an "S" after the part number for M6-35 studs instead of the standard 1/4-28 - 1" studs. Fast recovery available.
Specification
DESCRIPTION | specification | conditions | VALUE |
---|---|---|---|
Maximum Repetitive Reverse Voltage | VRRM | 25600 V | |
Maximum Forward Voltage Drop | IFAVM | At 50°C or Below, Natural Convection Cooling | 10 V |
Maximum Forward Voltage Drop | IFAVM | At 50°C or Below, Forced Air Cooling at 300 LFM | 25 V |
Maximum Forward Voltage Drop | VF | At IF = 5.0A, 25°C | 16 V |
Maximum Leakage Current | IR | At VRRM, 25°C | 100 μA |
Maximum Surge Current | IFSM | At 10mS | 950 A |
Maximum Junction Temperature | TJMAX | 150 °C | |
Operating Temperature Range | OP TEMP | -55 to 150 °C | |
Storage Temperature Range | STG TEMP | -55 to 150 °C | |
Body Length | L | Dimension | 10.4 in |
Body Height | H | Dimension | 3.75 in |