HVM40B
Notes
- Available with multiple power cord options for most mains configurations.
- Available with handle and rack mount options.
Specification
DESCRIPTION | specification | conditions | VALUE |
---|---|---|---|
Operational Temperature Range | OP TEMP | 0 to 50 °C | |
Operational Humidity | Humidity | Non Condensing | 0 to 80 % |
Storage Temperature Range | STORAGE TEMP | °C | |
Case Dimensions | Case Dimensions | Metric | 9.0 W x 3.5 H x 7.25 D cm |
Weight | Weight | Imperial | 4 lbs |
Electrical Input | Input | 50 - 60 Hz, 0.5 Amps Maximum | 100 to 250 VAC |
Measured Voltage | Measured Voltage | DC Only | 500 to 40,000 VDC |
Input Impedance | Input Impedance | 10 GΩ | |
Input HV Connector | HV-Insulated 40 kV | Alden F310RX | |
Input Return Connector | Binding Post | ||
Accuracy (High) | Accuracy (High) | 2,000 – 40,000 Volts | +/- 0.4 % |
Accuracty (Low) | Accuracty (Low) | 500 – 2,000 Volts | +/- 1.0 % |
Resolution | 4.5 | ||
Sampling Rate | 2 | ||
Display | LED | ||
Case Dimension | Case Dimensions | Imperial | 22.86 W x 8.89 H x 18.415 D in |
Weight | 1.8 | ||
fuse | Fuse | Slow Blow | 0.5 A / 250 VAC |