SH13A03Z1320S


Notes

  • The true VRRM of an MOV compensated unit is 2 times the max applied voltage. In this case the Max Applied Voltage of the assembly is limited by the Max Operating Voltage of the MOV used. Max Applied Voltage is the max safe peak voltage that can be repeatedly applied to the rectifier.

Request a Quote

Specification

DESCRIPTION specification conditions VALUE
Maximum Leakage CurrentIRAt VRMS100 μA
Maximum Surge CurrentIFSMAt 8.3 mS, TJ = 150°C150 A
Dimension - Overall LengthL18.5 in
Dimension - Overall LengthL218.5 in
Peak Inverse VoltageVRRMPer Leg145000 V
Maximum Applied voltageVMAV72500
Maximum Average Forward CurrentIFAVMAt 40 °C, Natural Convection1 A
Maximum Average Forward CurrentIFAVMAt 40 °C, In Oil1.5 A
Maximum Forward Voltage DropVFAt IFAVM, Per Leg208 V