UMR-A-40000P-30


Notes

  • Other hardware options available, see datasheet for details. Typically, convection cooled. Units operating at full power might require additional cooling to maintain case temperature below 65°C. Damage to the power supply may occur if not appropriately cooled during use.

Specification

DESCRIPTION specification conditions VALUE
Operational Humidity HumidityNon Condensing 0 to 95 %
Operating Altitude AltitudeSea Level to Vacuum
Storage Temperature Range STORAGE TEMP °C
Input Voltage VINominal 24 V
Input Voltage VIFull Output Power 23 - 30 V
Input Voltage VIDerated Output Power 10 - 32 V
Maximum Input Current IIStandby / Output Disable 80 mA
Maximum Input Current IINo Load, Max Vout 350 mA
Maximum Input Current IIMax Load, Max Vout 1600 mA
Maximum Input AC Ripple Current IACRNominal Input, Full Load 100 mA PP
Maximum Output Voltage VO40000 V
Maximum Output Power PO30 W
Maximum Output Current IO0.75 mA
Ripple Ripple (HF)1 Hz to 1 MHz (Full Load, Nominal Input) 0.064 % VPP
Output Capacitance CO1000 µF
Current Monitor Scaling IMON0.092 mA / V
Voltage Monitor Scaling VMONInto 10 Megaohm Meter, ±2% 1000:1 V
Operational Temperature Range Op Temp CaseCase Temperature at Full Load -40 to 65 °C
Temp Coefficient TCOEFF50 PPM / °C
Case Dimensions Case DimensionsMetric 119.38 L x 38.1 W x 25.13 L mm
Weight WeightMetric 222 g
Thermal Shock Thermal ShockMil-Std 810, Method 503-4, Proc. II -40 to 65 °C
Shock ShockMil-Std 810, Method 516.5, Proc. IV 20 G
VibrationVibrationMil-Std 810, Method 514.5, Fig. 514.5C-310 G