UMR-HPC-20000N-60


Notes

  • Typically, convection cooled. Units operating at full power might require additional cooling to maintain case temperature below 65°C. Damage to the power supply may occur if not appropriately cooled during use. For specification differences and additional information on V05/V10 options see data sheet.

Specification

DESCRIPTION specification conditions VALUE
Operational HumidityHumidityNon Condensing0 to 95 %
Operating AltitudeAltitudeSea Level to Vacuum
Storage Temperature RangeSTORAGE TEMP °C
Input VoltageVINominal24 V
Input VoltageVIFull Output Power23 - 30 V
Input VoltageVIDerated Output Power10 - 32 V
Maximum Input CurrentIIStandby / Output Disable90 mA
Maximum Input CurrentIINo Load, Max Vout500 mA
Maximum Input CurrentIIMax Load, Max Vout3250 mA
Maximum Input AC Ripple CurrentIACRNominal Input, Full Load150 mA PP
Maximum Output VoltageVO-20000 V
Maximum Output PowerPO60 W
Maximum Output CurrentIO3 mA
RippleRipple (HF)1 Hz to 1 MHz (Full Load, Nominal Input)1.000 % VPP
Output CapacitanceCO0.00088 µF
Current Monitor ScalingIMON0.65 mA / V
Voltage Monitor ScalingVMONInto 10 Megaohm Meter, ±2%1000:1 V
Operational Temperature RangeOp Temp CaseCase Temperature at Full Load-40 to 65 °C
Temp CoefficientTCOEFF50 PPM / °C
Case DimensionsCase DimensionsMetric203.2 L x 114.3 W x 27.0 H mm
WeightWeightMetric1200 g
Thermal ShockThermal ShockMil-Std 810, Method 503-4, Proc. II-40 to 65 °C
ShockShockMil-Std 810, Method 516.5, Proc. IV20 G
VibrationVibrationMil-Std 810, Method 514.5, Fig. 514.5C-310 G