UMR-HPC-4000P-250
Notes
- Typically, convection cooled. Units operating at full power might require additional cooling to maintain case temperature below 65°C. Damage to the power supply may occur if not appropriately cooled during use. For specification differences and additional information on V05/V10 options see data sheet.
Specification
DESCRIPTION | specification | conditions | VALUE |
---|---|---|---|
Operational Humidity | Humidity | Non Condensing | 0 to 95 % |
Operating Altitude | Altitude | Sea Level to Vacuum | |
Storage Temperature Range | STORAGE TEMP | °C | |
Input Voltage | VI | Nominal | 24 V |
Input Voltage | VI | Full Output Power | 23 - 30 V |
Input Voltage | VI | Derated Output Power | 10 - 32 V |
Maximum Input Current | II | Standby / Output Disable | 90 mA |
Maximum Input Current | II | No Load, Max Vout | 500 mA |
Maximum Input Current | II | Max Load, Max Vout | 6300 mA |
Maximum Input AC Ripple Current | IACR | Nominal Input, Full Load | 200 mA PP |
Maximum Output Voltage | VO | 4000 V | |
Maximum Output Power | PO | 250 W | |
Maximum Output Current | IO | 62 mA | |
Ripple | Ripple (HF) | 1 Hz to 1 MHz (Full Load, Nominal Input) | 1.000 % VPP |
Output Capacitance | CO | 0.10 µF | |
Current Monitor Scaling | IMON | 52 mA / V | |
Voltage Monitor Scaling | VMON | Into 10 Megaohm Meter, ±2% | 100:1 V |
Operational Temperature Range | Op Temp Case | Case Temperature at Full Load | -40 to 65 °C |
Temp Coefficient | TCOEFF | 50 PPM / °C | |
Case Dimensions | Case Dimensions | Metric | 203.2 L x 114.3 W x 27.0 H mm |
Weight | Weight | Metric | 1164 g |
Thermal Shock | Thermal Shock | Mil-Std 810, Method 503-4, Proc. II | -40 to 65 °C |
Shock | Shock | Mil-Std 810, Method 516.5, Proc. IV | 20 G |
Vibration | Vibration | Mil-Std 810, Method 514.5, Fig. 514.5C-3 | 10 G |