Z130PA20A
Notes
- High Current Surge Rating
- High Energy
- Easy to Mount
- Device data taken at 25°C
- Typical response time is less than 15 nanoseconds
Specification
| DESCRIPTION | specification | conditions | VALUE |
|---|---|---|---|
| Maximum Continuous Operating Voltage AC | VRRMS | 130 V | |
| Maximum Continuous Operating Voltage DC | VDC | 170 V | |
| Minimum Varistor Voltage | VN(DC) MIN | At 1 mA | 184 V |
| Nominal Varistor Voltage | VN(DC) NOM | At 1 mA | 205 V |
| Maximum Varistor Voltage | VN(DC) MAX | At 1 mA | 243 V |
| Maximum Clamping Voltage | VC | At IC | 340 V |
| Clamping Current | IC | 100 A | |
| Maximum Peak Surge Current | IP | 10000 A | |
| Maximum Energy | WMAX | At 2 ms | 100 J |
| Typical Capacitance | C | At 1 kHz | 2300 pF |
| Maximum Power Dissipation | PD MAX | 1.0 W | |
| Operational Temperature Range | OP TEMP | -55 to 125 °C | |
| Storage Temperature Range | STORAGE TEMP | °C |