Z60BD681


Notes

  • Device data taken at 25 °C. Typical response time is less than 15 nanoseconds.

Specification

DESCRIPTION specification conditions VALUE
Operational Temperature RangeOP TEMP-55 to 125 °C
Typical CapacitanceCAt 1 kHz6200 pF
Maximum Continuous Operating Voltage ACVRRMS420 V
Maximum Continuous Operating Voltage DCVDC560 V
Minimum Varistor VoltageVN(DC) MINAt 1 mA612 V
Nominal Varistor VoltageVN(DC) NOMAt 1 mA680 V
Maximum Varistor VoltageVN(DC) MAXAt 1 mA748 V
Maximum EnergyWMAXAt 2 ms1500 J
Maximum Clamping VoltageVCAt IC1120 V
Clamping CurrentIC500 A
Maximum Peak Surge CurrentIP70000 A
Dimension - Maximum ThicknessTMAX5 mm
Storage Temperature RangeSTORAGE TEMP °C