G20PE


Notes

  • These parts are replacements for Unitrode. Custom parts available, please consult factory.

Specification

DESCRIPTION specification conditions VALUE
Maximum Repetitive Reverse VoltageVRRM20000 V
Maximum Forward Voltage DropVFAt IFAVM, 25°C35 V
Maximum Average Forward CurrentIFAVMAt 55°C15 mA
Maximum Leakage CurrentIRAt VRRM, 25°C0.20 μA
Maximum Surge CurrentIFSMAt 8.3mS3 A
Maximum Reverse Recovery TimeTRRAt IF = 0.5 IFAVM, IR = -IFAVM, IRR = -0.25 IFAVM100 nS
Operating Temperature RangeOP TEMP-55 to 150 °C
Storage Temperature RangeSTG TEMP-55 to 150 °C
LengthLDimension1 in