PMT-15-1500P-0.8



Specification

DESCRIPTION specification conditions VALUE
Operational Temperature Range OP TEMP-10 to 65 °C
Operational Humidity HumidityNon Condensing 5 to 95 %
Operating Altitude Altitude0 to 10000 Ft
Storage Temperature Range STORAGE TEMP °C
Input Voltage VI15 V
Maximum Output Voltage VO1500 V
Maximum Output Power PO0.8 W
Temperature Coefficient TCOEFF0.01 % / °C
Case Dimensions Case DimensionsMetric 1.811 W x 0.472 H x 0.969 D cm
Weight< 0.1
Input TypeDC
Maximum Input Power PI< 2.25 W
Maximum Output Current - Primary IOP0.53 mA
Voltage Regulation Volt RegAt Dynamic Load < 0.02 % VDC
Ripple (Volts Peak to Peak) RippleAt Full Load, Nominal Input <0.01 % VPP
Line Regulation Line RegOutput Change Over AC or DC Input Range At Nominal Load < 0.01 % VDC
Load Regulation Load RegOutput Change From No Load to Full Load < 0.02 % VDC
Stability StabilityOver 8 hours, after 30 minute warm-up. At 25 °C ambient, fixed load, and fixed input. < 0.10 % VDC
Control TypeAnalog Signal
Voltage Control Control Voltage0 - 5 VDC
Voltage Range Controlled Control Range0 - 100 % VO
Reference Voltage VREF5 VDC
Voltage Monitor VMONInto 10 Megaohm Meter 1 V / kV
Case DimensionCase DimensionsImperial4.6 W x 2.46 H x 1.2 D in
Weight< 0.045