SE55A09Z0111S


Notes

  • The true VRRM of an MOV compensated unit is 2 times the max applied voltage. In this case the Max Applied Voltage of the assembly is limited by the Max Operating Voltage of the MOV used. Max Applied Voltage is the max safe peak voltage that can be repeatedly applied to the rectifier.

Specification

DESCRIPTION specification conditions VALUE
Maximum Leakage CurrentIRAt VRMS100 μA
Dimension - Overall LengthL11.75 in
Dimension - Overall LengthL211.75 in
Peak Inverse VoltageVRRMPer Leg4000 V
Maximum Applied voltageVMAV2000
Maximum Average Forward CurrentIFAVMAt 40 °C, Natural Convection2.4 A
Maximum Average Forward CurrentIFAVMAt 40 °C, In Oil4 A
Maximum Forward Voltage DropVFAt IFAVM, Per Leg4.4 V
Maximum Surge CurrentIFSMAt 8.3 mS, Per Leg370 A