T52P2000F500


Notes

  • For specific QRR values, contract the factory.
  • For specific TRR values, contact the factory.

Request a Quote

Specification

DESCRIPTION specification conditions VALUE
Maximum Repetitive Reverse VoltageVRRM500 V
Maximum Allowable Junction TemperatureTJMAX125 °C
Maximum Forward Surge CurrentITSMAt TJMAX16000 A
Maximum Forward Voltage DropVTMAt On-State Current2.6 V
Maximum Case TemperatureTC65 °C
Critical Rate of Rise (Delta I / Delta T)ΔI/ΔT800 A/µS
Maximum I2t For FusingI2TAt 60Hz1060
Maximum Gate Trigger VoltageVGT3 V
Maximum Gate Trigger CurrentIGT150 mA
Maximum Critical Rate of Rise of Off-State VoltageΔV/ΔTAt TJMAX500 V/µS
Maximum Turn Off TimetQAt TJMAX35 µS
Maximum Holding CurrentIH500 mA
Typical Thermal Resistance (Junction to Case)RθJC2Both sides cooled0.023 °C/W
Maximum Average Forward CurrentIT(AV)At TC (Case Temperature)2000 A
On-State CurrentITM4000 A
Mounting ForceFM5500 lbs
Maximum Reverse Leakage CurrentIRRMAt TJMAX65 mA