UMR-HPC-15000P-60

Features

  • Adjustable Output
  • ARC/Short Protected
  • Current Monitor
  • Encapsulated
  • High Efficiency >80%
  • Low Ripple
  • Metal Case
  • Regulated
  • Voltage Monitor
Cable Thumping Capacitor Charging Dielectric Testing Electrostatic Air Cleaners Electrostatic Oil Cleaners Electrostatic Painting ESD Testing Ink Jet Printing Ion Beams Ionizers Leakage Testing Photomultipliers Piezoelectric Driver Powder Coating Pulse Generators UltraSonics
Specification Conditions Value
VI Nominal 24 V
VI Full Output Power 23 - 30 V
VI Derated Output Power 10 - 32 V
II Standby / Output Disable 90 mA
II No Load, Max Vout 500 mA
II Max Load, Max Vout 3250 mA
IACR Nominal Input, Full Load 150 mA PP
VO 15000 V
PO 60 W
IO 4 mA
Ripple (HF) 1 Hz to 1 MHz (Full Load, Nominal Input) 1 % VPP
CO 0.0011 µF
Load Reg. - S No Load to Full Load, Max Vout < 0.01 % VDC
Line Reg. Nominal Input, Max Vout, Full Power < 0.08 % VDC
Stability Over 8 hours, after 30 minute warm-up. At 25 °C ambient, fixed load, and fixed input. 0.01 % VDC
Stability Over 24 hours, after 30 minute warm-up. At 25 °C ambient, fixed load, and fixed input. 0.02 % VDC
IMON Full Scale Signal 4 mA / V
VMON Into 10 Megaohm Meter, ±2% 1000:1 V
Op. Temp. Case Case Temperature at Full Load -40 to 65 °C
TCOEFF 50 PPM / °C
Store Temp. -55 to 105 °C
Humidity Non Condensing 0 to 95 %
Altitude Sea Level to Vacuum
Case Dimensions Metric 203.2 L x 114.3 W x 27.0 H mm
Weight Metric 1200 g
Thermal Shock Mil-Std 810, Method 503-4, Proc. II -40 to 65 °C
Shock Mil-Std 810, Method 516.5, Proc. IV 20 G
Vibration Mil-Std 810, Method 514.5, Fig. 514.5C-3 10 G
Title / Description
3D Model for 125V to 6kV UMR-HPC Series High Voltage Power Supplies
3D Model for 20kV to 30kV UMR-HPC Series High Voltage Power Supplies
3D Model for 8kV to 15kV UMR-HPC Series High Voltage Power Supplies
Quick Start Guide for UMR-HPC Series High Voltage Power Supplies
  • Typically, convection cooled. Units operating at full power might require additional cooling to maintain case temperature below 65°C. Damage to the power supply may occur if not appropriately cooled during use.
  • For specification differences and additional information on V05/V10 options see data sheet.
CE cRUus RoHS