Z34SQ142


Notes

  • Device data taken at 25 °C. Typical response time is less than 15 nanoseconds.

Request a Quote

Specification

DESCRIPTION specification conditions VALUE
Operational Temperature RangeOP TEMP-55 to 125 °C
Typical CapacitanceCAt 1 kHz1100 pF
Maximum Continuous Operating Voltage ACVRRMS880 V
Maximum Continuous Operating Voltage DCVDC1150 V
Minimum Varistor VoltageVN(DC) MINAt 1 mA1260 V
Nominal Varistor VoltageVN(DC) NOMAt 1 mA1400 V
Maximum Varistor VoltageVN(DC) MAXAt 1 mA1540 V
Maximum EnergyWMAXAt 2 ms1300 J
Maximum Clamping VoltageVCAt IC2290 V
Clamping CurrentIC300 A
Maximum Peak Surge CurrentIP40000 A
Maximum Peak Surge CurrentIPFor 8 x 20 μs Pulse25000 A
Dimension - Maximum WidthDMAX37 mm
Dimension - Maximum ThicknessTMAX13.8 mm
Dimension - Lead OffsetY11.9 mm
Maximum Power DissipationPD MAX1.4 W
Storage Temperature RangeSTORAGE TEMP °C