PMT-12-1000N-0.5

Features

  • Adjustable Output
  • ARC/Short Protected
  • Encapsulated
  • Low Ripple
  • Metal Case
  • Regulated
  • Voltage Monitor
Detectors Dielectric Testing Electrostatic Air Cleaners Electrostatic Painting ESD Testing High Voltage Bias Ink Jet Printing Ion Beams Ionizers Leakage Testing Particle Analyzer Photomultipliers Piezoelectric Driver Powder Coating UltraSonics
Specification Conditions Value
VI 12 V
VO -1000 V
Input Type DC
PI < 1.8 W
PO 0.5 W
IOP 0.5 mA
Volt Reg. At Dynamic Load < 0.02 % VDC
Ripple At Full Load, Nominal Input < 0.005 % VPP
Line Reg. Output Change Over AC or DC Input Range At Nominal Load < 0.01 % VDC
Load Reg. Output Change From No Load to Full Load < 0.02 % VDC
Stability Over 8 hours, after 30 minute warm-up. At 25 °C ambient, fixed load, and fixed input. < 0.10 % VDC
Control Type Analog Signal
Control Voltage 0 - 5 VDC
Control Range 0 - 100 % VO
VREF 5 VDC
VMON Into 10 Megaohm Meter 1 V / kV
Op. Temp. -10 to 65 °C
TCOEFF 0.01 % / °C
Store Temp. -40 to 85 °C
Humidity Non Condensing 5 to 95 %
Altitude 0 to 10000 Ft.
Case Dimensions Imperial 1.811 W x 0.472 H x 0.969 D in.
Case Dimensions Metric 4.6 W x 2.46 H x 1.2 D cm
Weight Imperial < 0.1 lbs.
Weight Metric < 0.045 kg
CE cRUus RoHS